Фильтр ФСКО-1000

Filter is designed for cleaning of flue gases from the burning furnace for hard radioactive waste, which have been cleaned in scrubber and filter for flue gases cleaning system from hard and liquid fine dispersed (0,1-3 micro m) aerosol particles.


Working load (air filtering capacity), m3/h 1000
 Эффективность улавливания дисперсной фазы аэрозоля при номинальном расходе 1000м 3/час,% 99,9
 Массовая доля концентрации аэрозолей в очищаемом газе: 
 - жидких, г/м 3 до 5
 - твердых, мг/м 3 до 0,5
Initial filter resistance in working load,Pa, not more
 800
Filter resistance: 
 - in the conditions of self-cleaning during the fog filtration, Pa, not more
 3500
- in the conditions of accumulated dry percipitates
( the percipitate 100 g/m2, Pa
 2500
Overall dimensions of the filter, mm, not more: 
 - external diameter, mm 1186
- height, mm 1040
Weight, kg 325
 